Equipment Checklist for AASHTO T 23
Making Strength Specimens

 
All equipment shall be inspected for compliance with appropriate dimensions, as stated in each standard, as well as to determine if it is in satisfactory operating condition (i.e.; adherence of mortar, deformed molds, etc.). Inspection shall occur at least annually, or whenever there is reason to suspect nonconformance with the standard.

 

 

  Item Cylinder molds
  Description Steel, cast iron, or other nonabsorbent, nonreactive material of a size consistent with the nominal maximum size of the coarse aggregate
     
  Calibration Item Dimensions, shape, water leakage
  Calibration Procedure

AASHTO T 23 Sec. 4.2.1
AASHTO M 205

  Calibration Interval See AASHTO M 205
 

  Item Tamping Rod
  Description 5/8" diameter and 24" in length and 3/8" diameter and 12" in length straight steel rods, with hemispherical tips
     
  Calibration Item See the general statement above.
  Calibration Procedure  
  Calibration Interval  
 

  Item Internal Vibrator
  Description 7000 vibrations per minute, or greater, while in use and of appropriate size .
     
  Calibration Item Frequency
  Calibration Procedure AASHTO T 23 Sec. 4.5
With a vibrating reed tachometer
  Calibration Interval None stated
 

  Item External Vibrator
  Description 3600 vibrations per minute, or greater..
     
  Calibration Item Frequency
  Calibration Procedure AASHTO T 23 Sec. 4.5
With a vibrating reed tachometer
  Calibration Interval None stated
 

  Item Mallet
  Description Rubber or rawhide, 1.25 + 0.50 lb..
     
  Calibration Item Mass
  Calibration Procedure Weigh with a balance
  Calibration Interval None stated
 

  Item Thermometer
  Description For measuring the temperature of the concrete
     
  Calibration Item Temperature reading
  Calibration Procedure ASTM C 1064 via AASHTO T 23 Sec. 7.3
  Calibration Interval See ASTM C 1064
 

  Item Miscellaneous Tools
  Description Shovels, scoops, handheld float, trowel
     
  Calibration Item See the general statement above.
  Calibration Procedure  
  Calibration Interval  
 

  Item Mold cover material
  Description Nonabsorbent, nonreactive plate or sheet of impervious plastic
     
  Calibration Item See the general statement above
  Calibration Procedure  
  Calibration Interval  
 

  Item Specimen storage during initial curing
  Description Storage unit with cooling and/or heating devices as well as a max/min thermometer
     
  Calibration Item Calcium hydroxide saturation, thermometer
  Calibration Procedure AASHTO M 201
  Calibration Interval See AASHTO M 201