Item |
Cylinder molds & lids |
| |
Description |
Steel, cast iron or other non-absorbent,
non-reactive material of a size consistent with the nominal maximum size
of the coarse aggregate |
| |
|
|
| |
Calibration Item |
Dimensions, shape, water leakage |
| |
Calibration Procedure |
AASHTO T 23
|
| |
Calibration Interval |
See AASHTO M 205 |
| |
|
|
| |
Item |
Tamping rods |
| |
Description |
Straight steel rods (5/8" x
24" or 3/8" x 12") |
| |
|
|
| |
Calibration Item |
Verify dimensions |
| |
Calibration Procedure |
Measure dimensions |
| |
Calibration Interval |
12 months |
| |
|
|
| |
Item |
Internal vibrator |
| |
Description |
7000 vibrations per minute, or greater,
while in use and of a appropriate size |
| |
|
|
| |
Calibration Item |
Frequency |
| |
Calibration Procedure |
AASHTO
T 23 Sec. 4.5 |
| |
Calibration Interval |
12 months |
| |
|
|
| |
Item |
External vibrator |
| |
Description |
3600 vibrations per minute, or greater |
| |
|
|
| |
Calibration Item |
Frequency |
| |
Calibration Procedure |
AASHTO
T 23, Sec. 4.5 |
| |
Calibration Interval |
12 months |
| |
|
|
| |
Item |
Mallet |
| |
Description |
Rubber or rawhide |
| |
|
|
| |
Calibration Item |
Mass |
| |
Calibration Procedure |
Weigh with a balance |
| |
Calibration Interval |
12 months |
| |
|
|
| |
Item |
Balance |
| |
Description |
Accuracy within 0.3% of of test
load |
| |
|
|
| |
Calibration Item |
Verify mass readings |
| |
Calibration Procedure |
AASHTO
M 231 |
| |
Calibration Interval |
12 months |
| |
|
|
| |
Item |
Thermometer |
| |
Description |
Concrete temperature |
| |
|
|
| |
Calibration Item |
Temperature readings |
| |
Calibration Procedure |
Verify measurement |
| |
Calibration Interval |
12 months |
| |
|
|
| |
Item |
Miscellaneous Equipment |
| |
Description |
Shovels, scoops, handheld float,
trowel, sampling and mixing pan |
| |
|
|
| |
Calibration Item |
Check physical condition |
| |
Calibration Procedure |
Visual |
| |
Calibration Interval |
12 months |
| |
|
|
| |
Item |
Concrete mixer |
| |
Description |
Capable of throroughly mixing adequate
size samples |
| |
|
|
| |
Calibration Item |
Check physical condition and operation |
| |
Calibration Procedure |
Visual |
| |
Calibration Interval |
12 months |
| |
|
|
| |
|
|