Equipment Checklist for AASHTO M 205
Molds for Forming Concrete Test Cylinders

 
All equipment shall be inspected for compliance with appropriate dimensions, as stated in each standard, as well as to determine if it is in satisfactory operating condition (i.e.; adherence of mortar, deformed molds, etc.). Inspection shall occur at least annually, or whenever there is reason to suspect nonconformance with the standard.

 

 

  Item Reusable molds
  Description Nonabsorbant mold meeting requirements for shape, dimensions, perpendicularity, plane end faces, and water leakage
     
  Calibration Item Shape
  Calibration Procedure See Section 3.1.2
  Calibration Interval  
     
  Calibration Item Diameter and height
  Calibration Procedure See Section 3.1.2
  Calibration Interval  
     
  Calibration Item Perpendicularity
  Calibration Procedure See Section 3.1.2
  Calibration Interval  
     
  Calibration Item Plane end faces
  Calibration Procedure See Section 3.1.2
  Calibration Interval  
     
  Calibration Item Water leakage
  Calibration Procedure See Section 7.4
  Calibration Interval  
     
    Check at least 3 molds, selected at random, from each shipment.
 

  Item Single use molds
  Description Sheet metal, pastic, treated paper, or other material that meets requirements for water leakage, absorptivity, elongation, and construction
     
  Calibration Item Water leakage
  Calibration Procedure See Sections 5.2.1 and 7.3
  Calibration Interval  
     
  Calibration Item Absorptivity
  Calibration Procedure See Sections 5.2.2 and 7.3
  Calibration Interval  
     
  Calibration Item Elongation
  Calibration Procedure See Sections 5.2.3 and 7.3
  Calibration Interval  
     
  Calibration Item Construction
  Calibration Procedure See Sections 5
  Calibration Interval  
     
    Check at least 3 molds, selected at random, from each shipment.